AC Cord Co. Technical Information

SVT Constructions

Vacuum cleaner service cord. All plastic construction. 2 or 3 conductors, 300 volt.





      Circular Bare Conductor O.D. Insulation Wall Insulated Conductor Jacket Wall O.D Overall Diameter    
  No. of Stranding Mil Square "A" "B" O.D "C" "D"   Net Weight
AWG Conductors AWG mm Area mm in. mm in. mm in. mm. in mm in mm Amp (kg/km) (lbs/Mft)
18 2 41/34 41/0.160 1,627 0.830 0.047 1.190 0.015 0.380 0.077 1.950 0.030 0.760 0.240 6.10 10 31 47
18 3 41/34 41/0.160 1,627 0.830 0.047 1.190 0.015 0.380 0.077 1.950 0.030 0.760 0.255 6.480 10 38 56
17 2 52/34 52/0.160 2,097 1.070 0.053 1.346 0.015 0.380 0.083 2.108 0.030 0.760 0.242 6.150 12 36 53
17 3 52/34 52/0.160 2,097 1.070 0.053 1.346 0.015 0.380 0.083 2.108 0.030 0.760 0.280 7.110 12 42 62
16 2 65/34 65/0.160 2,580 1.320 0.059 1.500 0.015 0.380 0.089 2.260 0.030 0.760 0.280 7.110 13 37 55
16 3 65/34 65/0.160 2,580 1.320 0.059 1.500 0.015 0.380 0.089 2.260 0.030 0.760 0.290 7.370 13 48 71